Built from the type’s procedures, with the handbook’s own figures and checklists · Jon’s review shown on each checklist
Use alongside your aircraft’s own approved checklist. A reference in our own words, drawn from the type’s published procedures, with each figure labelled with where it comes from. Your aircraft’s approved flight manual and checklist always govern: limits and procedures differ between models, years, modifications and operators.
14 checklists for the Piper PA-28R-201 Arrow: 13 normal (preflight: cabin, preflight: walk-around, before starting engine, starting engine, taxi, before takeoff: run-up and 7 more), and 1 for emergencies (engine failure in flight).
Speeds at a glance
Best angle, VX
78 knots gear up, 72 gear down, flaps up
Best rate, VY
90 knots gear up, 78 gear down, flaps up
Best glide
79 knots at 2,750 pounds, gear up, flaps up
Maneuvering, VA
118 knots at 2,750 pounds, 96 at 1,865
Flap extension, VFE
103 knots
Landing gear
129 knots to extend and extended, 107 to retract
Structural cruising, VNO
146 knots
Never exceed, VNE
183 knots
Normal approach
75 knots, flaps 40 degrees
Demonstrated crosswind
17 knots
From Piper Arrow PA-28R-201 POH, SN 2844001 and up, Report VB-1612, issued July 1995, revised 2004. These are the figures the Co-pilot gives by voice: ask it for “best glide”. Your own aircraft’s approved flight manual always governs.
Checklists for
Piper PA-28R-201 Arrow
Handbook figures
Source: Piper Arrow PA-28R-201 POH, SN 2844001 and up, Report VB-1612, issued July 1995, revised 2004. 14 checklists.
Piper PA-28R-201 Arrow1 of 14
Preflight: cabin
7 items · Handbook figures
Documents aboard: airworthiness, registration, handbook, weight and balance
Control lock removed
Magnetos off, key out
Avionics and electrical switches off
Master on: fuel quantity checked, gear down lights green; master off
Fire extinguisher secure and charged
Loose items stowed
End of Preflight: cabin · Piper PA-28R-201 Arrow
Piper PA-28R-201 Arrow2 of 14
Preflight: walk-around
11 items · Handbook figures
Tail and control surfaces: free, secure, hinges and attachments checked
Fuel drained from every sump and the strainer: no water or sediment